To Measure Is To Know
 
 

You have not viewed any products recently.

 
 

Product Manuals, Brochures, and Documents

Our Forms and Documents Library contains the product manuals and service and technical bulletins for our products.

All files are downloadable Acrobat PDF files (Click here to download Adobe Acrobat Reader).

You can search by item number or product name.

Category:

Oct 09, 2017 PDF Document 3665BG Bird Guard - Technical Bulletins, SpecSheets
User's Guide to 3665BG. Install Spikes correctly, attach ring. Contents include Plastic ring, nut, 10 14-guage metal spikes (3.75"), lock washer, 1.75" screw.
Sep 13, 2017 PDF Document 6435FS TDR 350 Manual - Product Manuals
Soil moisture is a critical, and potentially highly variable, component of the soil environment. Time domain reflectometry is a proven technology for quickly and accurately determining volumetric water content (VWC) in soil. Electrical conductivity (EC) is a function of the moisture and salt in the soil. The meter also measures soil surface temperature.
Aug 29, 2017 PDF Document 3900 ET WatchDog Pup Stations Manual - Product Manuals
Wireless Mesh Network The Retriever & Pups wireless sensor network uses a mesh style of communication, which allows any Pup within the network to wirelessly route data from another Pup back to the Retriever. The size of a network can vary by growing conditions, topography, and user preference. The mesh network is constrained to a maximum number of 16 Pups per network at a distance of 2500 ft (about ½ mile or ¾ kilometer), or less between Pups, with no more than four hops back to the Retriever for the most remote Pups.
Aug 28, 2017 PDF Document 3900 3905 ET WatchDog Pup Stations - Product Manuals
• WatchDog ET Pup Station • WatchDog Pup Weather Station • WatchDog Plant Disease Pup Station The Sensor Pup component of the Station has been preconfigured to use the included sensors. The Pup Weather and the Plant Disease Stations have port “A” available for a sensor of your choice. The Pup transmits sensor data to the Retriever either directly or via a Repeater Pup.
Aug 11, 2017 PDF Document TDR 300 Soil Moisture Meter Product Manual - Product Manuals
Soil moisture is a critical and potentially highly varia-ble component of the soil environment. Time-domain reflectometry is a proven technology for quickly and accurately determining volumetric water content (VWC) in soil.
Aug 10, 2017 PDF Document 2220WP Field Scout EC450 Data Logger - Product Manuals
The integrated data logger allows the user to easily collect field data with the EC 450 meter. The logger can be used with or without GPS/DGPS. After a set of data has been collected, it is transferred to a PC using the included software. The data is in ASCII text file format and can be exported into mapping software or popular spreadsheet software for analysis.
Aug 10, 2017 PDF Document Field Scout EC450 Data Logger - Product Manuals
The integrated data logger allows the user to easily collect field data with the EC 450 meter. The logger can be used with or without GPS/DGPS. After a set of data has been collected, it is transferred to a PC using the included software. The data is in ASCII text file format and can be exported into mapping software or popular spreadsheet software for analysis.
May 30, 2017 PDF Document 6445FS_TDR_150_manual_(web) - Product Manuals
Soil moisture is a critical and potentially highly variable component of the soil environment. Time domain reflectometry is a proven technology for quickly and accurately determining volumetric water content (VWC) in soil. Electrical conductivity (EC) is a function of the moisture and salt in the soil. The meter also measures soil surface temperature. The user can quickly transition between taking VWC readings in standard and high-clay mode.
May 10, 2017 PDF Document 3349CN Sprayer Station Console User Guide - Product Manuals
Thank you for purchasing the WatchDog Sprayer Station Console. The Console is designed to be used with the WatchDog Sprayer Station, and will provide an accurate indication and record of the environmental conditions around a vehicle, whether it is stationary or in motion. It allows for real-time measurement of weather data before, during, and after a field operation.
Apr 26, 2017 PDF Document 3672 Alarm Output Module - Product Manuals, SpecSheets
The Alarm Output Module (AOM) is a dry contact, control relay that operates as either a normally-open or normally-closed single pole switch. The output is rated at 1 amp AC or DC. It should be used with low voltage control signals due to its exposed terminal contacts.
Mar 22, 2017 PDF Document SpecWare Packages Insert - Manhattan Cable Drivers - Product Manuals, Technical Bulletins
Software Driver for USB-Serial Cable (item 3661USB) Installation Instructions
Mar 22, 2017 PDF Document SpecWare Packages Insert - FTDI Cable Drivers - Technical Bulletins, SpecSheets
Software Driver for FTDI Cable (item 3661U) Installation Instructions
Oct 18, 2016 PDF Document 3401 3402 Temperature\/RH Pens - Product Manuals
In addition to temperature and RH, the 3402 also displays dew point and wet bulb temperatures. Please read this manual thoroughly before using your meter.
Oct 05, 2016 PDF Document 3365DC Digital Pulse Adapter Cable - Product Manuals
The 3665DC Digital Pulse Adapter Cable is to be used with pulse-type rain collectors that have two-wire interface to a 100 Ohm resistor and reed switch. The switch is normally open; tipping closes the switch, connecting the circuit through the resistor.
Sep 28, 2016 PDF Document 2265FS FieldScout Direct Soil EC Meter - Product Manuals
Congratulations on the purchase of your FieldScout Direct Soil EC Meter. This instrument has been specifically designed for direct measurement of salts in soil media as well as water or nutrient solutions. This manual describes how to use your meter and keep it working accurately for many years. Please read it thoroughly to get effective performance from your meter. 2265FSTP, 2265PROBE, 2265FST24P
Results: 290 Record(s) Found.